L44 — UV LED Flood Curing Lamp, 4″ × 4″ Irradiation Area
Incure L44 delivers 78% more curing area than the L33 in a 4″ × 4″ array — the largest L-Series™ model that still fits within the C131C, C131D, and C141C chamber envelopes. Where the L33 covers 9 sq. in., the L44 covers 16 sq. in. in a single exposure: a full board section, a large conformal coating panel, or a multi-joint pattern too wide for the L33 to reach in one pass. Step above the L44 to the L64 and C-Series™ chamber compatibility drops off entirely.
78% More Curing Area Than the L33 — Still Sized for C-Series™ Chambers
The L44 is 16 sq. in. versus the L33's 9 sq. in. — the same C131C, C131D, and C141C chamber compatibility, but with enough area to cover 4-inch assemblies in one uninterrupted pass. The L64, the next model up, has no chamber-compatible option: moving to the L44 is the last opportunity to gain area while retaining controlled-environment batch cure capability.
Maximizes Throughput in Chamber-Based Processes
In a timed batch process inside a C-Series™ chamber, cure time is fixed by the adhesive, not by the lamp area. The L44 fills that fixed time window with the widest possible irradiation zone — curing more assembly area per cycle than any other L-Series™ model that fits the chamber. For processes that run multiple cure cycles per hour, the larger footprint directly reduces the number of repositioning steps per batch.
3,100 mW/cm² Across a 4″ × 4″ Area (144 LEDs at 385/395/405 nm)
144-LED array; peak irradiance at 2″ working distance: 3,100 mW/cm² at 385 nm, 395 nm, or 405 nm; 2,600 mW/cm² at 365 nm. Static uniformity 0.78 at 2.0″ working distance. Wavelength factory-configured at order (365 / 385 / 395 / 405 nm); LED life rated at greater than 20,000 hours.
| UV Output | |
| Model | L44 |
| Irradiation Area | 4″ × 4″ (102 mm × 102 mm) |
| LED Array | 144 LEDs |
| Peak Intensity @ 2″ — 365 nm | 2,600 mW/cm² |
| Peak Intensity @ 2″ — 385/395/405 nm | 3,100 mW/cm² |
| Recommended Curing Distance | 1″ – 3″ |
| Static Uniformity @ 2.0″ | 0.78 |
| Static Uniformity @ 3.0″ | 0.62 |
| Control & Operation | |
| Available Wavelengths | 365 nm / 385 nm / 395 nm / 405 nm (factory-configured at order) |
| Operating Modes | Timer & Continuous (Front-Panel Switchable) |
| Control Interface | LCD Front Panel; Foot-Switch Input; PLC Digital I/O |
| Power & Cooling | |
| Power Input | 100 – 240 V, 50/60 Hz (auto-ranging) |
| Cooling | Forced-Air, Louvers |
| Compatibility & Durability | |
| Chamber Compatible | Incure C131C / C131D / C141C |
| LED Lifespan | > 20,000 hours |
| Ordering | |
| P/N Format | L44-[Wavelength] |
| Wavelength Code | 365 / 385 / 395 / 405 |
| Example P/N | L44-365 |
Irradiance values measured at 100% output intensity at the specified working distance. Peak intensity at 385/395/405 nm configurations exceeds 365 nm output for the L44 array — this is a characteristic of the LED die efficiency at these wavelengths. Static uniformity measured as minimum/maximum intensity ratio across the irradiation area. LED lifespan rated at greater than 20,000 operating hours under standard conditions; no recalibration or bulb replacement required during normal service life. The L44 is the largest L-Series™ model compatible with Incure C131C, C131D, and C141C chambers; larger models (L64 and above) do not have a chamber-compatible option in the C-Series™ range.