A panel-level assembly that’s larger than the lamp above it doesn’t just take longer to cure — it takes multiple repositioned exposures, and each reposition is another opportunity for an uncured gap at the overlap line.

Four Times the Curing Area of the F200P in a Single Pass

The Incure F900P is a large-area programmable UV arc flood curing lamp covering a 16″×12″ area — four times the F200P’s 8″×6″ footprint — in a single, uninterrupted pass, at the same 350 mW/cm² intensity and the same programmable dose control as the F200P. For panel-level assembly, multi-board fixturing, or large-format bonding where the F200P would need multiple passes or repositioning to cover the full area, the F900P removes those steps entirely. It requires 200–240 VAC only and is compatible with the Incure B201 UV cure chamber.

192 Square Inches — What the F200P Cannot Cover in One Pass

192 square inches in a single exposure is four times the 48 square inches the F200P covers. That eliminates the multiple repositioning steps otherwise required when curing large panels, multi-board fixtures, or wide-format bond lines with a compact flood lamp. The 16″×12″ aperture fits standard EMS panel dimensions directly, reducing panel-level cure time from several partial exposures down to a single trigger cycle.

Confirming whether a panel or fixture actually needs the F900P’s full-area coverage, versus repositioning a smaller lamp, is worth checking before ordering. Email Us with the panel dimensions and Incure can confirm the right fit.

Fully Programmable for Automated Assembly Lines

An LCD display, digital keypad, and fully programmable operation enable automated exposure sequences — dose, interval, and repeat cycles can all be set for line-integrated batch curing rather than a single manual trigger. The integrated retractable shade shutter keeps all four lamps continuously lit between cycles, removing the warm-up delay a cold-started arc lamp would otherwise introduce between parts.

2,400W Across a 16″×12″ Area at 350 mW/cm²

Four individually replaceable 600W metal halide arc lamps deliver 2,400W total arc power — broadband UVA (315–400 nm), UVB (280–315 nm), and visible output to 420 nm — at 350 mW/cm² across the full 16″×12″ area at 2.0-inch working distance, 175 mW/cm² at 3.0 inches. Lamp life is rated at roughly 2,000 hours per bulb, and because each of the four lamps is individually replaceable, end-of-life maintenance is done one bulb at a time rather than as a full-unit replacement.

Physical and Electrical Specifications

The F900P weighs 26.6 lb at 17.45″×23″×7.75″, forced-air cooled. Unlike the smaller F-Series™ models, the F900P requires 200–240 VAC supply only — it is not auto-ranging, which is worth confirming against available facility power before installation.

The Only Chamber Sized for This Lamp

The F900P’s 16″×12″ curing area exceeds what the standard B500 chamber can accommodate — only the Incure B/C-Series™ UV Cure Chambers line’s B201 model, with its 12.5″×22.0″×16.4″ interior, is built around this lamp’s footprint. For fully enclosed, shielded batch curing of large assemblies, the B201 is the pairing to specify.

Where the F900P Sits in the F-Series™ Range

The F900P is the large-format outlier in the Incure F-Series™ UV Arc Flood Lamps lineup — every other model in the range tops out at an 8″×6″ curing area, and the F900P’s 16″×12″ footprint is purpose-built for the panel and multi-board scale that the rest of the family isn’t sized to reach.

Four-Lamp Redundancy Changes the Downtime Calculation

Because the F900P’s 2,400W total output comes from four individually replaceable 600W lamps rather than a single arc source, a bulb reaching end of life doesn’t necessarily mean taking the whole unit offline the way it would on a single-lamp F-Series™ model. While all four lamps still need to be functional for the rated full-area 350 mW/cm² output, individually replaceable bulbs mean maintenance is a per-lamp swap rather than a full-head replacement — a real consideration for a large-format line where unplanned downtime on the largest lamp in the F-Series™ range has an outsized production impact compared to a bench-mount unit.

Sizing Facility Power Before Committing to the F900P

Because the F900P requires 200–240 VAC and is explicitly not auto-ranging, unlike every other model in the F-Series™ lineup, a facility running on standard 100–120 VAC circuits needs to confirm dedicated 200–240 VAC service is available before specifying this model — retrofitting power for a single large-format lamp after installation is a meaningfully bigger project than swapping in an auto-ranging bench-mount unit would be. This is worth confirming early in the specification process alongside the B201 chamber requirement, since both represent facility-level commitments beyond the lamp purchase itself.

Confirming Power and Chamber Requirements Before Installation

Because the F900P is not auto-ranging and requires a dedicated chamber for enclosed operation, confirming both facility power and chamber compatibility during the specification phase avoids a mismatch at install. Operators should also confirm eyewear meets the Incure Vison™ UV eye protection rating for this output level. For help specifying an F900P and B201 pairing for a large-format process, Contact Our Team.