{"id":13719,"date":"2026-01-02T23:53:29","date_gmt":"2026-01-02T23:53:29","guid":{"rendered":"https:\/\/incurelab.com\/wp\/best-thermally-conductive-epoxy-the-ultimate-guide"},"modified":"2026-09-12T01:03:25","modified_gmt":"2026-09-12T01:03:25","slug":"best-thermally-conductive-epoxy-the-ultimate-guide","status":"publish","type":"post","link":"https:\/\/incurelab.com\/wp\/best-thermally-conductive-epoxy-the-ultimate-guide","title":{"rendered":"Why a Thermally Conductive Epoxy Bond Underperforms Its Datasheet W\/mK"},"content":{"rendered":"<p>A component running hotter than its thermal model predicted usually gets blamed on the epoxy&#8217;s conductivity number \u2014 but the datasheet W\/mK almost never accounts for what actually happens to that number once the material leaves the lab and enters a real bond line.<\/p>\n<h3>The Datasheet Number Describes a Test Sample, Not Your Assembly<\/h3>\n<p>A thermal conductivity figure on a data sheet is measured under controlled conditions \u2014 a defined sample thickness, a specific cure schedule, ideal filler dispersion. The actual thermal resistance of a bond in production depends on bond line thickness, filler settling, void content, and cure completeness, none of which the headline W\/mK number captures on its own. A design that specs purely off the data sheet figure without accounting for these process variables is specifying a number that its actual bond line may never achieve.<\/p>\n<h3>Root Cause One: Bond Line Thickness Variance<\/h3>\n<p>Thermal resistance scales directly with bond line thickness, and a dispensing process that isn&#8217;t tightly controlled can produce meaningful thickness variance from unit to unit \u2014 a bond line twice as thick as intended roughly doubles the thermal resistance contributed by the adhesive layer, regardless of how good the base material&#8217;s conductivity rating is. Confirming actual bond line thickness on a cross-sectioned sample, rather than assuming the dispense program delivers a consistent result, is the first thing worth checking when a thermal interface underperforms.<\/p>\n<h3>Root Cause Two: Filler Settling in Two-Part Systems<\/h3>\n<p>In two-part thermally conductive epoxies, the conductive filler can settle out of suspension during storage, particularly in slower-moving inventory. If a batch isn&#8217;t adequately re-agitated before mixing and dispensing, later-dispensed material from the same container can carry a meaningfully lower filler loading than the first material dispensed \u2014 and therefore lower actual conductivity \u2014 even though the container&#8217;s label reflects the formulation&#8217;s nominal filler content. This is a process-control issue rather than a material defect, and it&#8217;s diagnosed by comparing thermal performance across a dispensing session rather than assuming uniform performance throughout.<\/p>\n<h3>Root Cause Three: Voids at the Thermal Interface<\/h3>\n<p>A void in a structural bond is primarily a mechanical stress concentrator; a void in a thermal interface is a much more direct problem, since trapped air conducts heat orders of magnitude worse than the surrounding filled epoxy. Even a modest void percentage concentrated at the interface can meaningfully raise measured thermal resistance above what the bulk material&#8217;s conductivity would predict, and voids at a thermal interface are often invisible without dedicated inspection, since the bond can still look structurally sound at the same time.<\/p>\n<h3>Root Cause Four: Incomplete Cure Reducing Filler Packing Efficiency<\/h3>\n<p>Efficient heat conduction through a filled polymer depends on filler particles achieving sufficient proximity to each other \u2014 the percolation network that carries phonon transport through the matrix. An incomplete or rushed cure can leave that network less fully developed than a properly cured sample, quietly reducing effective thermal conductivity below what the same formulation would achieve under its specified cure schedule.<\/p>\n<h3>Root Cause Five: CTE Mismatch Opening a Gap Over Time<\/h3>\n<p>A bond that started with acceptable thermal performance can degrade over service life if CTE mismatch between the epoxy and the substrates it bonds creates progressive microcracking or partial delamination under thermal cycling \u2014 the same mechanism covered in depth in <a href=\"https:\/\/incurelab.com\/wp\/how-cte-mismatch-causes-adhesive-bond-failure\">how CTE mismatch drives adhesive bond failure<\/a>. A thermal interface that measured well at time-zero and degrades gradually points toward this mechanism rather than an initial material or process defect.<\/p>\n<h3>Diagnosing With ASTM D5470<\/h3>\n<p>Testing actual bond-line thermal resistance against ASTM D5470 \u2014 the standard method for thermal transmission properties of thermally conductive electrical insulation materials \u2014 on a representative production sample is the only way to confirm whether the real-world number matches the data sheet claim. Without testing to this shared standard, comparing one supplier&#8217;s W\/mK figure against another&#8217;s, or against your own measured result, isn&#8217;t really a valid comparison, since testing methodology differences alone can produce different numbers for identical material.<\/p>\n<h3>A Diagnostic Sequence<\/h3>\n<ol>\n<li><strong>Cross-section a sample<\/strong> to confirm actual bond line thickness against the design target.<\/li>\n<li><strong>Check for void content specifically at the interface<\/strong>, not just overall bond integrity.<\/li>\n<li><strong>Compare thermal performance across a dispensing session<\/strong> to catch filler-settling drift in two-part systems.<\/li>\n<li><strong>Confirm the cure schedule was fully executed<\/strong>, including any required post-cure hold.<\/li>\n<li><strong>Test to ASTM D5470<\/strong> on a representative sample rather than relying on the data sheet figure alone.<\/li>\n<\/ol>\n<p>If a thermal interface is running hotter than expected and you&#8217;ve ruled out the obvious mechanical causes, <a href=\"mailto:support@incurelab.com\">Email Us<\/a> with your bond-line thickness data and cure schedule, and our technical team can help identify which of these five causes is most likely responsible.<\/p>\n<h3>Specifying With Margin Built In<\/h3>\n<p>Once the real bond-line thermal resistance is understood, specifying a formulation with margin above the theoretical minimum required \u2014 rather than the tightest possible fit to a calculated requirement \u2014 accounts for the process variance this analysis reveals. Incure&#8217;s Epo-Weld\u2122 thermally conductive line documents filler chemistry and electrical-insulation properties specifically so this kind of process-versus-datasheet analysis has real numbers to work from, and the electrical-insulation distinction between grades is documented in <a href=\"https:\/\/incurelab.com\/wp\/epo-weld-hecc-high-emissive-ceramic-coatings-by-substrate-and-service-temperature\">Incure&#8217;s HECC ceramic coatings guide<\/a> for a related high-temperature filler-chemistry comparison.<\/p>\n<p>A thermal interface that fails quietly inside a sealed enclosure months after assembly is a far more expensive problem than the extra process-control step that would have caught it at manufacture. <a href=\"https:\/\/www.incurelab.com\/contact\">Contact Our Team<\/a> to review your specific bond-line data against ASTM D5470 test requirements.<\/p>\n<p>Visit <a href=\"https:\/\/www.incurelab.com\">www.incurelab.com<\/a> for more information.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>A component running hotter than its thermal model predicted usually gets blamed on the epoxy&#8217;s conductivity number \u2014 but the datasheet W\/mK almost never accounts for what actually happens to that number once the material leaves the lab and enters a real bond line. The Datasheet Number Describes a Test Sample, Not Your Assembly A [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"ocean_front_end_style_editor":"no","ocean_post_layout":"","ocean_both_sidebars_style":"","ocean_both_sidebars_content_width":0,"ocean_both_sidebars_sidebars_width":0,"ocean_sidebar":"","ocean_second_sidebar":"","ocean_disable_margins":"enable","ocean_add_body_class":"","ocean_shortcode_before_top_bar":"","ocean_shortcode_after_top_bar":"","ocean_shortcode_before_header":"","ocean_shortcode_after_header":"","ocean_has_shortcode":"","ocean_shortcode_after_title":"","ocean_shortcode_before_footer_widgets":"","ocean_shortcode_after_footer_widgets":"","ocean_shortcode_before_footer_bottom":"","ocean_shortcode_after_footer_bottom":"","ocean_display_top_bar":"default","ocean_display_header":"default","ocean_header_style":"","ocean_center_header_left_menu":"","ocean_custom_header_template":"","ocean_custom_logo":0,"ocean_custom_retina_logo":0,"ocean_custom_logo_max_width":0,"ocean_custom_logo_tablet_max_width":0,"ocean_custom_logo_mobile_max_width":0,"ocean_custom_logo_max_height":0,"ocean_custom_logo_tablet_max_height":0,"ocean_custom_logo_mobile_max_height":0,"ocean_header_custom_menu":"","ocean_menu_typo_font_family":"","ocean_menu_typo_font_subset":"","ocean_menu_typo_font_size":0,"ocean_menu_typo_font_size_tablet":0,"ocean_menu_typo_font_size_mobile":0,"ocean_menu_typo_font_size_unit":"px","ocean_menu_typo_font_weight":"","ocean_menu_typo_font_weight_tablet":"","ocean_menu_typo_font_weight_mobile":"","ocean_menu_typo_transform":"","ocean_menu_typo_transform_tablet":"","ocean_menu_typo_transform_mobile":"","ocean_menu_typo_line_height":0,"ocean_menu_typo_line_height_tablet":0,"ocean_menu_typo_line_height_mobile":0,"ocean_menu_typo_line_height_unit":"","ocean_menu_typo_spacing":0,"ocean_menu_typo_spacing_tablet":0,"ocean_menu_typo_spacing_mobile":0,"ocean_menu_typo_spacing_unit":"","ocean_menu_link_color":"","ocean_menu_link_color_hover":"","ocean_menu_link_color_active":"","ocean_menu_link_background":"","ocean_menu_link_hover_background":"","ocean_menu_link_active_background":"","ocean_menu_social_links_bg":"","ocean_menu_social_hover_links_bg":"","ocean_menu_social_links_color":"","ocean_menu_social_hover_links_color":"","ocean_disable_title":"default","ocean_disable_heading":"default","ocean_post_title":"","ocean_post_subheading":"","ocean_post_title_style":"","ocean_post_title_background_color":"","ocean_post_title_background":0,"ocean_post_title_bg_image_position":"","ocean_post_title_bg_image_attachment":"","ocean_post_title_bg_image_repeat":"","ocean_post_title_bg_image_size":"","ocean_post_title_height":0,"ocean_post_title_bg_overlay":0.5,"ocean_post_title_bg_overlay_color":"","ocean_disable_breadcrumbs":"default","ocean_breadcrumbs_color":"","ocean_breadcrumbs_separator_color":"","ocean_breadcrumbs_links_color":"","ocean_breadcrumbs_links_hover_color":"","ocean_display_footer_widgets":"default","ocean_display_footer_bottom":"default","ocean_custom_footer_template":"","ocean_post_oembed":"","ocean_post_self_hosted_media":"","ocean_post_video_embed":"","ocean_link_format":"","ocean_link_format_target":"self","ocean_quote_format":"","ocean_quote_format_link":"post","ocean_gallery_link_images":"on","ocean_gallery_id":[],"footnotes":""},"categories":[1],"tags":[],"class_list":["post-13719","post","type-post","status-publish","format-standard","hentry","category-uncategorized","entry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Why a Thermally Conductive Epoxy Bond Underperforms Its Datasheet W\/mK - INCURE INC.<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/incurelab.com\/wp\/best-thermally-conductive-epoxy-the-ultimate-guide\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Why a Thermally Conductive Epoxy Bond Underperforms Its Datasheet W\/mK - INCURE INC.\" \/>\n<meta property=\"og:description\" content=\"A component running hotter than its thermal model predicted usually gets blamed on the epoxy&#8217;s conductivity number \u2014 but the datasheet W\/mK almost never accounts for what actually happens to that number once the material leaves the lab and enters a real bond line. The Datasheet Number Describes a Test Sample, Not Your Assembly A [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/incurelab.com\/wp\/best-thermally-conductive-epoxy-the-ultimate-guide\" \/>\n<meta property=\"og:site_name\" content=\"INCURE INC.\" \/>\n<meta property=\"article:published_time\" content=\"2026-01-02T23:53:29+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-12T01:03:25+00:00\" \/>\n<meta name=\"author\" content=\"Incure Content Team\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Incure Content Team\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/best-thermally-conductive-epoxy-the-ultimate-guide#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/best-thermally-conductive-epoxy-the-ultimate-guide\"},\"author\":{\"name\":\"Incure Content Team\",\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/#\\\/schema\\\/person\\\/53482b163015e8f48dc86f4132515727\"},\"headline\":\"Why a Thermally Conductive Epoxy Bond Underperforms Its Datasheet W\\\/mK\",\"datePublished\":\"2026-01-02T23:53:29+00:00\",\"dateModified\":\"2026-09-12T01:03:25+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/best-thermally-conductive-epoxy-the-ultimate-guide\"},\"wordCount\":929,\"publisher\":{\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/#organization\"},\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/best-thermally-conductive-epoxy-the-ultimate-guide\",\"url\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/best-thermally-conductive-epoxy-the-ultimate-guide\",\"name\":\"Why a Thermally Conductive Epoxy Bond Underperforms Its Datasheet W\\\/mK - INCURE INC.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/#website\"},\"datePublished\":\"2026-01-02T23:53:29+00:00\",\"dateModified\":\"2026-09-12T01:03:25+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/best-thermally-conductive-epoxy-the-ultimate-guide#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/incurelab.com\\\/wp\\\/best-thermally-conductive-epoxy-the-ultimate-guide\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/best-thermally-conductive-epoxy-the-ultimate-guide#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Why a Thermally Conductive Epoxy Bond Underperforms Its Datasheet W\\\/mK\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/#website\",\"url\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/\",\"name\":\"INCURE INC.\",\"description\":\"Engineered Solutions. Trusted Worldwide\",\"publisher\":{\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/#organization\",\"name\":\"INCURE INC.\",\"url\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/incure-logo.jpeg\",\"contentUrl\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/incure-logo.jpeg\",\"width\":164,\"height\":45,\"caption\":\"INCURE INC.\"},\"image\":{\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/#\\\/schema\\\/person\\\/53482b163015e8f48dc86f4132515727\",\"name\":\"Incure Content Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/85e856c6e17c9c44477ea1e0964ef5dc19c2a1ef29a741bb9bb742fcfc644fcc?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/85e856c6e17c9c44477ea1e0964ef5dc19c2a1ef29a741bb9bb742fcfc644fcc?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/85e856c6e17c9c44477ea1e0964ef5dc19c2a1ef29a741bb9bb742fcfc644fcc?s=96&d=mm&r=g\",\"caption\":\"Incure Content Team\"},\"url\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/author\\\/kimleelcy\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Why a Thermally Conductive Epoxy Bond Underperforms Its Datasheet W\/mK - INCURE INC.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/incurelab.com\/wp\/best-thermally-conductive-epoxy-the-ultimate-guide","og_locale":"en_US","og_type":"article","og_title":"Why a Thermally Conductive Epoxy Bond Underperforms Its Datasheet W\/mK - INCURE INC.","og_description":"A component running hotter than its thermal model predicted usually gets blamed on the epoxy&#8217;s conductivity number \u2014 but the datasheet W\/mK almost never accounts for what actually happens to that number once the material leaves the lab and enters a real bond line. The Datasheet Number Describes a Test Sample, Not Your Assembly A [&hellip;]","og_url":"https:\/\/incurelab.com\/wp\/best-thermally-conductive-epoxy-the-ultimate-guide","og_site_name":"INCURE INC.","article_published_time":"2026-01-02T23:53:29+00:00","article_modified_time":"2026-09-12T01:03:25+00:00","author":"Incure Content Team","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Incure Content Team","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/incurelab.com\/wp\/best-thermally-conductive-epoxy-the-ultimate-guide#article","isPartOf":{"@id":"https:\/\/incurelab.com\/wp\/best-thermally-conductive-epoxy-the-ultimate-guide"},"author":{"name":"Incure Content Team","@id":"https:\/\/incurelab.com\/wp\/#\/schema\/person\/53482b163015e8f48dc86f4132515727"},"headline":"Why a Thermally Conductive Epoxy Bond Underperforms Its Datasheet W\/mK","datePublished":"2026-01-02T23:53:29+00:00","dateModified":"2026-09-12T01:03:25+00:00","mainEntityOfPage":{"@id":"https:\/\/incurelab.com\/wp\/best-thermally-conductive-epoxy-the-ultimate-guide"},"wordCount":929,"publisher":{"@id":"https:\/\/incurelab.com\/wp\/#organization"},"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/incurelab.com\/wp\/best-thermally-conductive-epoxy-the-ultimate-guide","url":"https:\/\/incurelab.com\/wp\/best-thermally-conductive-epoxy-the-ultimate-guide","name":"Why a Thermally Conductive Epoxy Bond Underperforms Its Datasheet W\/mK - INCURE INC.","isPartOf":{"@id":"https:\/\/incurelab.com\/wp\/#website"},"datePublished":"2026-01-02T23:53:29+00:00","dateModified":"2026-09-12T01:03:25+00:00","breadcrumb":{"@id":"https:\/\/incurelab.com\/wp\/best-thermally-conductive-epoxy-the-ultimate-guide#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/incurelab.com\/wp\/best-thermally-conductive-epoxy-the-ultimate-guide"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/incurelab.com\/wp\/best-thermally-conductive-epoxy-the-ultimate-guide#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/incurelab.com\/wp\/"},{"@type":"ListItem","position":2,"name":"Why a Thermally Conductive Epoxy Bond Underperforms Its Datasheet W\/mK"}]},{"@type":"WebSite","@id":"https:\/\/incurelab.com\/wp\/#website","url":"https:\/\/incurelab.com\/wp\/","name":"INCURE INC.","description":"Engineered Solutions. Trusted Worldwide","publisher":{"@id":"https:\/\/incurelab.com\/wp\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/incurelab.com\/wp\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/incurelab.com\/wp\/#organization","name":"INCURE INC.","url":"https:\/\/incurelab.com\/wp\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/incurelab.com\/wp\/#\/schema\/logo\/image\/","url":"https:\/\/incurelab.com\/wp\/wp-content\/uploads\/2025\/07\/incure-logo.jpeg","contentUrl":"https:\/\/incurelab.com\/wp\/wp-content\/uploads\/2025\/07\/incure-logo.jpeg","width":164,"height":45,"caption":"INCURE INC."},"image":{"@id":"https:\/\/incurelab.com\/wp\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/incurelab.com\/wp\/#\/schema\/person\/53482b163015e8f48dc86f4132515727","name":"Incure Content Team","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/85e856c6e17c9c44477ea1e0964ef5dc19c2a1ef29a741bb9bb742fcfc644fcc?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/85e856c6e17c9c44477ea1e0964ef5dc19c2a1ef29a741bb9bb742fcfc644fcc?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/85e856c6e17c9c44477ea1e0964ef5dc19c2a1ef29a741bb9bb742fcfc644fcc?s=96&d=mm&r=g","caption":"Incure Content Team"},"url":"https:\/\/incurelab.com\/wp\/author\/kimleelcy"}]}},"rttpg_featured_image_url":null,"rttpg_author":{"display_name":"Incure Content Team","author_link":"https:\/\/incurelab.com\/wp\/author\/kimleelcy"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/incurelab.com\/wp\/category\/uncategorized\" rel=\"category tag\">Uncategorized<\/a>","rttpg_excerpt":"A component running hotter than its thermal model predicted usually gets blamed on the epoxy&#8217;s conductivity number \u2014 but the datasheet W\/mK almost never accounts for what actually happens to that number once the material leaves the lab and enters a real bond line. The Datasheet Number Describes a Test Sample, Not Your Assembly A&hellip;","_links":{"self":[{"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/posts\/13719","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/comments?post=13719"}],"version-history":[{"count":2,"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/posts\/13719\/revisions"}],"predecessor-version":[{"id":24290,"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/posts\/13719\/revisions\/24290"}],"wp:attachment":[{"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/media?parent=13719"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/categories?post=13719"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/tags?post=13719"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}