{"id":15898,"date":"2026-04-30T08:56:51","date_gmt":"2026-04-30T08:56:51","guid":{"rendered":"https:\/\/incurelab.com\/wp\/why-does-high-temperature-epoxy-resin-crack-after-curing"},"modified":"2026-04-30T08:56:51","modified_gmt":"2026-04-30T08:56:51","slug":"why-does-high-temperature-epoxy-resin-crack-after-curing","status":"publish","type":"post","link":"https:\/\/incurelab.com\/wp\/why-does-high-temperature-epoxy-resin-crack-after-curing","title":{"rendered":"Why Does High Temperature Epoxy Resin Crack After Curing"},"content":{"rendered":"<p>Cracking in a freshly cured high temperature epoxy resin is one of the more alarming outcomes a process engineer can encounter \u2014 the material is supposed to emerge from the cure cycle as a solid, integrated bond or coating, not as a network of fracture lines. Yet it happens, and when it does, it almost always traces to one of a handful of identifiable causes. Understanding each of them allows systematic diagnosis and corrective action.<\/p>\n<h3>Cause 1: Excessive Internal Stress From Rapid Cure<\/h3>\n<p>Epoxy resins shrink as they cure \u2014 the crosslinking reaction draws molecules together into a denser network than existed in the liquid state. For most systems this volumetric shrinkage is 2%\u20135%. In a freely suspended film or a symmetrically constrained casting, shrinkage is accommodated uniformly. In an adhesive bonded to rigid, non-shrinking substrates, the substrate constrains the adhesive from shrinking freely \u2014 developing internal tensile stress in the adhesive as it tries to pull itself away from the bondline.<\/p>\n<p>When this internal stress exceeds the fracture strength of the partially cured resin \u2014 which is typically lower than the fully cured strength \u2014 cracking occurs. Rapid exothermic cure amplifies the problem: the heat generated by the curing reaction softens the partially cured resin momentarily, allowing it to relax. When the exotherm passes and the assembly cools, the relaxed dimensions become the new reference, and additional stress develops during the remainder of cure and during cooling. Particularly thick sections accumulate the most exothermic heat and are most prone to stress-cracking.<\/p>\n<p><strong>Corrective action:<\/strong> Reduce section thickness where possible. Use staged cure schedules that ramp temperature slowly rather than curing all at once. For bulk potting, mix in smaller batches and apply progressively. Slow-cure formulations with lower peak exotherm are available for thick-section applications.<\/p>\n<h3>Cause 2: Thermal Shock During or After Cure<\/h3>\n<p>High temperature post-cure schedules require heating the assembly and then cooling it. If cooling occurs too rapidly \u2014 by removing the part from the oven directly into ambient air \u2014 the surface contracts rapidly while the interior remains hot. The resulting temperature gradient creates tensile stress at the surface that can exceed the fracture stress of the brittle, highly crosslinked epoxy network.<\/p>\n<p>This failure pattern is recognized by surface cracks that appear immediately on removal from the oven or within the first minutes of cooling. Cracks from thermal shock are typically oriented perpendicular to the temperature gradient \u2014 in flat sections, they appear as surface cracks parallel to the plane; in cylindrical sections, as circumferential cracks.<\/p>\n<p><strong>Corrective action:<\/strong> Control the cooling rate. Allow assemblies to cool in the oven by turning off the heat and opening the door gradually. A cooling rate of 1\u00b0C\u20133\u00b0C per minute from post-cure temperature is conservative and appropriate for crack-sensitive systems. Do not transfer hot assemblies to cold fixtures or cold environments until the part temperature has approached ambient.<\/p>\n<h3>Cause 3: Brittleness in High Crosslink Density Systems<\/h3>\n<p>High Tg epoxy resins achieve their thermal stability through dense crosslinked networks \u2014 exactly the structural feature that also reduces elongation at break and fracture toughness. A system with a Tg of 260\u00b0C may have an elongation at break of 1%\u20132% at room temperature. When residual stress from cure or cooling exceeds the strain capacity of such a brittle material, fracture occurs.<\/p>\n<p>Cracking due to inherent brittleness is often observed in thick sections, complex geometries with stress concentrations at corners or edges, or applications where the adhesive is bonded to substrates with very different moduli.<\/p>\n<p><strong>Corrective action:<\/strong> Select a toughened high temperature formulation that incorporates rubber or thermoplastic modifiers. Toughened systems sacrifice some Tg \u2014 typically 10\u00b0C\u201330\u00b0C \u2014 in exchange for substantially improved fracture toughness (KIc) and elongation. For many applications the toughened system provides better overall performance in service despite the reduced Tg, because it survives the cure and handling stresses without cracking.<\/p>\n<p>Alternatively, redesign joint geometry to eliminate acute internal corners or abrupt section changes that concentrate residual stress.<\/p>\n<h3>Cause 4: Moisture in the System During Cure<\/h3>\n<p>Moisture on substrates or absorbed in hygroscopic components \u2014 particularly certain fillers and hardeners \u2014 can vaporize during elevated-temperature cure, generating internal voids and pressure that exceeds the cohesive strength of the partially cured resin. The result is internal cracking, often visible as a network of voids or cracks through the cross-section rather than on the surface.<\/p>\n<p>Moisture-induced cracking is most common in thick potting applications or laminates where internal moisture has no path to escape before the surface skins over.<\/p>\n<p><strong>Corrective action:<\/strong> Dry substrates and components before use. Cure hygroscopic fillers or hardener components at 80\u00b0C\u2013100\u00b0C for one to two hours before mixing. Use a ramp-and-hold cure schedule that allows moisture to escape at low temperatures before the surface gels.<\/p>\n<h3>Cause 5: Off-Ratio or Incompletely Mixed Material<\/h3>\n<p>Severely off-ratio or poorly mixed high temperature epoxy results in regions of uncured or partially cured material adjacent to properly cured regions. The differential shrinkage and modulus between these zones generates stress at their boundaries that can cause cracking. Off-ratio material may also have dramatically reduced mechanical properties \u2014 an uncured zone is essentially a plane of weakness.<\/p>\n<p><strong>Corrective action:<\/strong> Verify mix ratio accuracy with weighed components. Mix thoroughly with side-wall scraping and confirm visual uniformity before application. For static-mix cartridge systems, purge adequately before dispensing.<\/p>\n<p>Incure provides troubleshooting guidance for cracking in high temperature epoxy resin applications, including cure schedule optimization and formulation alternatives for crack-sensitive geometries.<\/p>\n<p>For help diagnosing cracking in your application and developing a corrective process, <a href=\"mailto:support@incurelab.com\">Email Us<\/a> and our engineering team will assist.<\/p>\n<p>Cracking after cure is a solvable problem in every case where the root cause is correctly identified. The five causes above cover the overwhelming majority of occurrences in practice.<\/p>\n<p><a href=\"https:\/\/www.incurelab.com\/contact\">Contact Our Team<\/a> to discuss cracking diagnosis and prevention.<\/p>\n<p>Visit <a href=\"https:\/\/www.incurelab.com\">www.incurelab.com<\/a> for more information.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Cracking in a freshly cured high temperature epoxy resin is one of the more alarming outcomes a process engineer can encounter \u2014 the material is supposed to emerge from the cure cycle as a solid, integrated bond or coating, not as a network of fracture lines. Yet it happens, and when it does, it almost [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":0,"comment_status":"","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"ocean_post_layout":"","ocean_both_sidebars_style":"","ocean_both_sidebars_content_width":0,"ocean_both_sidebars_sidebars_width":0,"ocean_sidebar":"","ocean_second_sidebar":"","ocean_disable_margins":"enable","ocean_add_body_class":"","ocean_shortcode_before_top_bar":"","ocean_shortcode_after_top_bar":"","ocean_shortcode_before_header":"","ocean_shortcode_after_header":"","ocean_has_shortcode":"","ocean_shortcode_after_title":"","ocean_shortcode_before_footer_widgets":"","ocean_shortcode_after_footer_widgets":"","ocean_shortcode_before_footer_bottom":"","ocean_shortcode_after_footer_bottom":"","ocean_display_top_bar":"default","ocean_display_header":"default","ocean_header_style":"","ocean_center_header_left_menu":"","ocean_custom_header_template":"","ocean_custom_logo":0,"ocean_custom_retina_logo":0,"ocean_custom_logo_max_width":0,"ocean_custom_logo_tablet_max_width":0,"ocean_custom_logo_mobile_max_width":0,"ocean_custom_logo_max_height":0,"ocean_custom_logo_tablet_max_height":0,"ocean_custom_logo_mobile_max_height":0,"ocean_header_custom_menu":"","ocean_menu_typo_font_family":"","ocean_menu_typo_font_subset":"","ocean_menu_typo_font_size":0,"ocean_menu_typo_font_size_tablet":0,"ocean_menu_typo_font_size_mobile":0,"ocean_menu_typo_font_size_unit":"px","ocean_menu_typo_font_weight":"","ocean_menu_typo_font_weight_tablet":"","ocean_menu_typo_font_weight_mobile":"","ocean_menu_typo_transform":"","ocean_menu_typo_transform_tablet":"","ocean_menu_typo_transform_mobile":"","ocean_menu_typo_line_height":0,"ocean_menu_typo_line_height_tablet":0,"ocean_menu_typo_line_height_mobile":0,"ocean_menu_typo_line_height_unit":"","ocean_menu_typo_spacing":0,"ocean_menu_typo_spacing_tablet":0,"ocean_menu_typo_spacing_mobile":0,"ocean_menu_typo_spacing_unit":"","ocean_menu_link_color":"","ocean_menu_link_color_hover":"","ocean_menu_link_color_active":"","ocean_menu_link_background":"","ocean_menu_link_hover_background":"","ocean_menu_link_active_background":"","ocean_menu_social_links_bg":"","ocean_menu_social_hover_links_bg":"","ocean_menu_social_links_color":"","ocean_menu_social_hover_links_color":"","ocean_disable_title":"default","ocean_disable_heading":"default","ocean_post_title":"","ocean_post_subheading":"","ocean_post_title_style":"","ocean_post_title_background_color":"","ocean_post_title_background":0,"ocean_post_title_bg_image_position":"","ocean_post_title_bg_image_attachment":"","ocean_post_title_bg_image_repeat":"","ocean_post_title_bg_image_size":"","ocean_post_title_height":0,"ocean_post_title_bg_overlay":0.5,"ocean_post_title_bg_overlay_color":"","ocean_disable_breadcrumbs":"default","ocean_breadcrumbs_color":"","ocean_breadcrumbs_separator_color":"","ocean_breadcrumbs_links_color":"","ocean_breadcrumbs_links_hover_color":"","ocean_display_footer_widgets":"default","ocean_display_footer_bottom":"default","ocean_custom_footer_template":"","ocean_post_oembed":"","ocean_post_self_hosted_media":"","ocean_post_video_embed":"","ocean_link_format":"","ocean_link_format_target":"self","ocean_quote_format":"","ocean_quote_format_link":"post","ocean_gallery_link_images":"on","ocean_gallery_id":[],"footnotes":""},"categories":[1],"tags":[],"class_list":["post-15898","post","type-post","status-publish","format-standard","hentry","category-uncategorized","entry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Why Does High Temperature Epoxy Resin Crack After Curing - INCURE INC.<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/incurelab.com\/wp\/why-does-high-temperature-epoxy-resin-crack-after-curing\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Why Does High Temperature Epoxy Resin Crack After Curing - INCURE INC.\" \/>\n<meta property=\"og:description\" content=\"Cracking in a freshly cured high temperature epoxy resin is one of the more alarming outcomes a process engineer can encounter \u2014 the material is supposed to emerge from the cure cycle as a solid, integrated bond or coating, not as a network of fracture lines. Yet it happens, and when it does, it almost [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/incurelab.com\/wp\/why-does-high-temperature-epoxy-resin-crack-after-curing\" \/>\n<meta property=\"og:site_name\" content=\"INCURE INC.\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-30T08:56:51+00:00\" \/>\n<meta name=\"author\" content=\"Tech\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tech\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/why-does-high-temperature-epoxy-resin-crack-after-curing#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/why-does-high-temperature-epoxy-resin-crack-after-curing\"},\"author\":{\"name\":\"Tech\",\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/#\\\/schema\\\/person\\\/1b7ce4c8fbcc74f8ea53bece903c16e0\"},\"headline\":\"Why Does High Temperature Epoxy Resin Crack After Curing\",\"datePublished\":\"2026-04-30T08:56:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/why-does-high-temperature-epoxy-resin-crack-after-curing\"},\"wordCount\":955,\"publisher\":{\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/#organization\"},\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/why-does-high-temperature-epoxy-resin-crack-after-curing\",\"url\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/why-does-high-temperature-epoxy-resin-crack-after-curing\",\"name\":\"Why Does High Temperature Epoxy Resin Crack After Curing - INCURE INC.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/#website\"},\"datePublished\":\"2026-04-30T08:56:51+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/why-does-high-temperature-epoxy-resin-crack-after-curing#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/incurelab.com\\\/wp\\\/why-does-high-temperature-epoxy-resin-crack-after-curing\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/why-does-high-temperature-epoxy-resin-crack-after-curing#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Why Does High Temperature Epoxy Resin Crack After Curing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/#website\",\"url\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/\",\"name\":\"INCURE INC.\",\"description\":\"Engineered Solutions. Trusted Worldwide\",\"publisher\":{\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/#organization\",\"name\":\"INCURE INC.\",\"url\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/incure-logo.jpeg\",\"contentUrl\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/incure-logo.jpeg\",\"width\":164,\"height\":45,\"caption\":\"INCURE INC.\"},\"image\":{\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/#\\\/schema\\\/person\\\/1b7ce4c8fbcc74f8ea53bece903c16e0\",\"name\":\"Tech\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c3ce256a26542500e368f9667cd42dce19b2efa6aa7b8bcc76d0efef5b18bfcb?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c3ce256a26542500e368f9667cd42dce19b2efa6aa7b8bcc76d0efef5b18bfcb?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c3ce256a26542500e368f9667cd42dce19b2efa6aa7b8bcc76d0efef5b18bfcb?s=96&d=mm&r=g\",\"caption\":\"Tech\"},\"url\":\"https:\\\/\\\/incurelab.com\\\/wp\\\/author\\\/tech\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Why Does High Temperature Epoxy Resin Crack After Curing - INCURE INC.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/incurelab.com\/wp\/why-does-high-temperature-epoxy-resin-crack-after-curing","og_locale":"en_US","og_type":"article","og_title":"Why Does High Temperature Epoxy Resin Crack After Curing - INCURE INC.","og_description":"Cracking in a freshly cured high temperature epoxy resin is one of the more alarming outcomes a process engineer can encounter \u2014 the material is supposed to emerge from the cure cycle as a solid, integrated bond or coating, not as a network of fracture lines. Yet it happens, and when it does, it almost [&hellip;]","og_url":"https:\/\/incurelab.com\/wp\/why-does-high-temperature-epoxy-resin-crack-after-curing","og_site_name":"INCURE INC.","article_published_time":"2026-04-30T08:56:51+00:00","author":"Tech","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Tech","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/incurelab.com\/wp\/why-does-high-temperature-epoxy-resin-crack-after-curing#article","isPartOf":{"@id":"https:\/\/incurelab.com\/wp\/why-does-high-temperature-epoxy-resin-crack-after-curing"},"author":{"name":"Tech","@id":"https:\/\/incurelab.com\/wp\/#\/schema\/person\/1b7ce4c8fbcc74f8ea53bece903c16e0"},"headline":"Why Does High Temperature Epoxy Resin Crack After Curing","datePublished":"2026-04-30T08:56:51+00:00","mainEntityOfPage":{"@id":"https:\/\/incurelab.com\/wp\/why-does-high-temperature-epoxy-resin-crack-after-curing"},"wordCount":955,"publisher":{"@id":"https:\/\/incurelab.com\/wp\/#organization"},"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/incurelab.com\/wp\/why-does-high-temperature-epoxy-resin-crack-after-curing","url":"https:\/\/incurelab.com\/wp\/why-does-high-temperature-epoxy-resin-crack-after-curing","name":"Why Does High Temperature Epoxy Resin Crack After Curing - INCURE INC.","isPartOf":{"@id":"https:\/\/incurelab.com\/wp\/#website"},"datePublished":"2026-04-30T08:56:51+00:00","breadcrumb":{"@id":"https:\/\/incurelab.com\/wp\/why-does-high-temperature-epoxy-resin-crack-after-curing#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/incurelab.com\/wp\/why-does-high-temperature-epoxy-resin-crack-after-curing"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/incurelab.com\/wp\/why-does-high-temperature-epoxy-resin-crack-after-curing#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/incurelab.com\/wp\/"},{"@type":"ListItem","position":2,"name":"Why Does High Temperature Epoxy Resin Crack After Curing"}]},{"@type":"WebSite","@id":"https:\/\/incurelab.com\/wp\/#website","url":"https:\/\/incurelab.com\/wp\/","name":"INCURE INC.","description":"Engineered Solutions. Trusted Worldwide","publisher":{"@id":"https:\/\/incurelab.com\/wp\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/incurelab.com\/wp\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/incurelab.com\/wp\/#organization","name":"INCURE INC.","url":"https:\/\/incurelab.com\/wp\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/incurelab.com\/wp\/#\/schema\/logo\/image\/","url":"https:\/\/incurelab.com\/wp\/wp-content\/uploads\/2025\/07\/incure-logo.jpeg","contentUrl":"https:\/\/incurelab.com\/wp\/wp-content\/uploads\/2025\/07\/incure-logo.jpeg","width":164,"height":45,"caption":"INCURE INC."},"image":{"@id":"https:\/\/incurelab.com\/wp\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/incurelab.com\/wp\/#\/schema\/person\/1b7ce4c8fbcc74f8ea53bece903c16e0","name":"Tech","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/c3ce256a26542500e368f9667cd42dce19b2efa6aa7b8bcc76d0efef5b18bfcb?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c3ce256a26542500e368f9667cd42dce19b2efa6aa7b8bcc76d0efef5b18bfcb?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c3ce256a26542500e368f9667cd42dce19b2efa6aa7b8bcc76d0efef5b18bfcb?s=96&d=mm&r=g","caption":"Tech"},"url":"https:\/\/incurelab.com\/wp\/author\/tech"}]}},"rttpg_featured_image_url":null,"rttpg_author":{"display_name":"Tech","author_link":"https:\/\/incurelab.com\/wp\/author\/tech"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/incurelab.com\/wp\/category\/uncategorized\" rel=\"category tag\">Uncategorized<\/a>","rttpg_excerpt":"Cracking in a freshly cured high temperature epoxy resin is one of the more alarming outcomes a process engineer can encounter \u2014 the material is supposed to emerge from the cure cycle as a solid, integrated bond or coating, not as a network of fracture lines. Yet it happens, and when it does, it almost&hellip;","_links":{"self":[{"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/posts\/15898","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/comments?post=15898"}],"version-history":[{"count":0,"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/posts\/15898\/revisions"}],"wp:attachment":[{"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/media?parent=15898"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/categories?post=15898"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/incurelab.com\/wp\/wp-json\/wp\/v2\/tags?post=15898"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}