Incure CDM™ / CDM™ Compact + F500x2A — The Highest Per-Head Intensity, Not the Highest Total Dose
Peak irradiance and total dose per pass sound like the same thing until a process actually needs one specifically and not the other — and the F500x2A is a useful case study in why that distinction matters. 590 mW/cm² Per Head — the Ceiling for Dual-UVA Configurations The Incure CDM™ / CDM™ Compact + F500x2A pairs either belt platform with two F500 UVA lamp heads in series — no UVC lamp head — delivering 590 mW/cm² at 365 nm per head, the highest per-lamp-head intensity of any dual-UVA configuration on the CDM™ fleet, ahead of the F400x2A's 490 mW/cm² and the F200x2A's 350 mW/cm² per head. For photoinitiator systems with a minimum irradiance threshold, or formulations that need above-threshold intensity to initiate the radical chain without extended exposure time, that peak intensity is the deciding spec. Doubling the F500x2AC at Every Belt Speed The single-assembly F500x2AC delivers 1,480 mJ/cm² UVA at 6 ft/min. The F500x2A places two F500 UVA heads in series on the same conveyor platform, doubling that to 2,960 mJ/cm² UVA at 6 ft/min — the same relationship the F400x2A and F200x2A hold to their respective single-assembly counterparts, just at the F500's higher per-head intensity. Where It Falls Short of the F400x2A — and Why Despite the higher per-head intensity, the F500x2A delivers less total energy per pass than the F400x2A at any given belt speed — 2,960 mJ/cm² versus 5,260 mJ/cm² UVA at 6 ft/min — because the F500's aperture is shorter in the belt-travel direction, so a part spends less total time under the beam even at higher instantaneous intensity. If total dose per pass is the primary requirement, the F400x2A is the correct configuration; if peak irradiance is what a formulation's photoinitiator system actually needs, the F500x2A is the right one despite the lower total-energy number. Sorting out whether a process needs peak intensity or total dose — they're not the same requirement — is worth confirming against the adhesive's actual photoinitiator data. Email Us with your formulation's specification and Incure can help match the configuration. A quick way to settle the question in practice: if a formulation cures reliably at a lower peak intensity given enough total exposure time, total dose is the governing variable and the F400x2A is likely the better fit. If cure quality drops sharply below a specific peak irradiance regardless of how much total time is allowed, the formulation has a genuine minimum-intensity threshold, and the F500x2A's higher per-head output is the configuration built to clear it. UVA-Only, Available on Both Platforms No UVC lamp head means no UVC ventilation or PPE overhead. The F500x2A is available on both the standard CDM™ (polypropylene belt) and CDM™ Compact (stainless-steel wire belt), sharing the same 3.0–6.5 inch curing height range and 5-inch maximum part width on either chassis. A mounting stand is not available for F500 configurations on either platform. Lamp head replacement is planned at the 1,000-hour threshold per head, and belt speed adjustment remains the only process control — no…