UV Arc Flood Conveyor Curing System — Incure CDM™ / CDM™ Compact + F400x2A
Incure CDM™ / CDM™ Compact F400x2A doubles the curing energy of the F400x2AC at the same belt speed — 5,260 mJ/cm² UVA at 6 ft/min versus 2,630 mJ/cm² for the single-assembly configuration. It's a UVA-only UV arc flood conveyor curing system pairing the CDM™ or CDM™ Compact 9″ belt conveyor with two F400 UVA lamp heads in series — no UVC lamp head — delivering 490 mW/cm² per lamp head at 365 nm across a maximum 5-inch part width, available on both the CDM™ (9″ polypropylene belt) and CDM™ Compact (9″ stainless-steel wire belt), both with a 3.0″–6.5″ curing height range. If your adhesive process is qualified under broadband UVA + UVC arc lamp exposure, specify the F400x2AC instead.
Doubles the UV Dose of the F400x2AC at the Same Belt Speed
The F400x2AC (single-assembly, 1 UVA + 1 UVC) delivers 2,630 mJ/cm² UVA at 6 ft/min from one lamp assembly. The F400x2A places two F400 UVA lamp heads in series on the same conveyor platform — parts pass under both heads in a single belt run, accumulating dose from each head consecutively. The result is 5,260 mJ/cm² UVA at 6 ft/min — exactly double the F400x2AC dose at the same belt speed, with no change in part width, conveyor platform, or system footprint beyond the two-head lamp assembly. For processes already running at target belt speed with the F400x2AC but not reaching full cure, the F400x2A doubles the available UV dose without slowing the line.
UVA-Only Output — No UVC Ventilation or UVC-Specific Compliance Requirements
The F400x2A uses two F400 UVA lamp heads in series — there is no UVC lamp head. UVA-only output means the conveyor does not require UVC ventilation, UVC shielding enclosures, or UVC-specific PPE protocols beyond standard UV safety practices. For facilities where UVC exposure management (air extraction, personnel exclusion zones, skin and eye protection above the UVA/UVB threshold) adds process complexity or compliance overhead, the F400x2A delivers the highest-energy F400 configuration without that requirement. If your adhesive cure schedule was qualified against a broadband UVA + UVC arc lamp, specify the F400x2AC — broadband qualification data cannot be directly applied to UVA-only process validation without re-testing.
21,000 mJ/cm² UVA at 1.5 ft/min — Maximum Dose for Deeply Pigmented or Thick-Layer Processes
At the slowest belt speed (1.5 ft/min), the F400x2A accumulates 21,000 mJ/cm² UVA across the 5-inch part width — the highest curing energy of any F400 configuration on the CDM™ or CDM™ Compact platform. This dose level supports deeply pigmented UV adhesive formulations where high pigment loading attenuates irradiance through the adhesive depth, or thick adhesive layers where UV penetration requires extended exposure time. At 6 ft/min the dose is 5,260 mJ/cm² UVA, and at 12 ft/min it is 2,640 mJ/cm² UVA — maintaining useful curing energy across the full belt speed range.
| Lamp Configuration | |
| Model | F400x2A |
| Configuration | F400x2A — 2 × F400 UVA lamp heads in series (UVA output only — no UVC lamp head) |
| Output Spectrum | UVA only (no UVC) |
| Cooling | Forced-air cooling / exhaust ventilation |
| Curing Performance | |
| Peak Intensity @ 2.0″ (365 nm) | 490 mW/cm² UVAper lamp head |
| Peak Intensity @ 2.0″ (385/395/405 nm) | 470 mW/cm² UVAper lamp head |
| UVA (UVV) Peak Intensity @ 2.5″ | 315 mW/cm² UVA · 300 mW/cm² UVV per lamp head |
| Curing Energy @ 1.5 ft/min (slowest) | 21,000 mJ/cm² UVA · 19,000 mJ/cm² UVV |
| Curing Energy @ 6.0 ft/min (nominal) | 5,260 mJ/cm² UVA · 4,760 mJ/cm² UVV |
| Curing Energy @ 12.0 ft/min (fastest) | 2,640 mJ/cm² UVA · 2,380 mJ/cm² UVV |
| Dynamic Uniformity @ 2.0″ | 0.82 |
| Static Uniformity @ 2.0″ | 0.75 |
| Light Source Useful Life | > 1,000 hours per lamphead |
| Typical Intensity Loss Over Useful Life | ≤ 45% |
| Conveyor Platform | |
| Belt Material | CDM™: 9″ Polypropylene (anti-static option available) CDM™ Compact: 9″ Stainless-Steel Wire Belt |
| Belt Speed | 1.5–12.0 ft/min (adjustable) |
| Maximum Part Width | 5 inches (127 mm) |
| Conveyor Curing Height | 3.0″–6.5″ (adjustable, both CDM™ and CDM™ Compact) |
| Mounting Stand | Optional |
| Control & Power | |
| External Control Port | Not available (manual conveyor speed only) |
| Power Input | 100–240 V, 50/60 Hz, auto-ranging |
| Ordering | |
| P/N — CDM™ | CDM-2xF400-365 |
| P/N — CDM™ Compact | CDMC-2xF400-365 |
F400x2A consists of two F400 UVA lamp heads installed in series on the conveyor — parts pass under both heads in a single belt run. No UVC lamp head is included. UVA and UVV curing energy values are estimated based on measured per-lamp-head irradiance at 2.0 and 2.5 inches (490 mW/cm² UVA per head) and belt speed; actual dose may vary depending on working distance, reflector age, bulb hours, part reflectivity, and measurement method. Dynamic and static uniformity values are typical conveyor measurements with ±5% variation. Lamp head replacement should be planned at the 1,000-hour threshold per head. No external PLC/RS-232 control port — F-series configurations are controlled by belt speed adjustment only. Mounting stand available as an optional accessory for F400 configurations. Maximum part width 5 inches (both CDM™ and CDM™ Compact platforms). Curing height 3.0″–6.5″ on both platforms.