F200 — Compact UV Arc Flood Curing Lamp
Incure F200 steps up from the F100 with 56% more intensity — 350 mW/cm² vs 225 mW/cm² — in the same 11 lb, 8″×6″ bench-mount housing. The 600W arc lamp cuts cure cycles where the F100's 400W falls short, without adding programming complexity. When the F200P's LCD timer is more than the process needs, the F200 delivers the same 350 mW/cm² with a simple rocker switch, an elapsed hour meter, and nothing to program.
56% More Intensity Than the F100 in the Same Housing
Same 8″×6″ curing area and 11 lb bench-mount form factor as the F100. The F200's 600W metal halide lamp produces 350 mW/cm² UVA at 2.0″ — against the F100's 225 mW/cm² from its 400W lamp. When cure time is the bottleneck and the F100's output is the constraint, the F200 is the direct step-up: same footprint, no new training, proportionally shorter cycles.
Shortens Cure Cycles Without Programming Overhead
Where the F200P's programmable timer and LCD keypad are more than a process requires, the F200 delivers the same 350 mW/cm² intensity with a rocker switch and an elapsed hour meter. Operators start and stop manually; the elapsed hour meter tracks lamp usage for scheduled maintenance. Compatible with the Incure B500 UV cure chamber for enclosed batch curing.
350 mW/cm² Across the Full 8″×6″ Area
600W metal halide arc lamp, UVA/UVB/visible to 420 nm. 175 mW/cm² at 3.0″. Forced-air cooling, auto-ranging 100–120/200–240 VAC. ~2,000-hour lamp life. 11 lb, 11″×10″×9″. UV Protective Goggles Included.
| Specifications | |
| Model | F200 |
| System Type | Compact UV Flood Curing System |
| Lamp Type | 600W Metal Halide Arc Lamp |
| Spectral Output | UVA (315–400 nm), UVB (280–315 nm), Visible to 420 nm |
| Curing Area | 8″ × 6″ |
| Output Intensity | |
| UVA Peak Intensity @ 2.0″ | 350 mW/cm² |
| UVA Peak Intensity @ 3.0″ | 175 mW/cm² |
| Power & Electrical | |
| Input Voltage | 100–120 / 200–240 VAC ±10%, auto-ranging |
| Input Frequency | 50 / 60 Hz |
| Physical | |
| Weight | 11 lb |
| Dimensions | 11″ × 10″ × 9″ |
| Control | Rocker Switch; Elapsed Hour Meter |
| Cooling | Forced Air |
| Lamp Life | ~2,000 hours |
| Chamber Compatibility | Compatible With Incure B500 UV Cure Chamber |
| Safety Equipment | UV Protective Goggles Included |
| Ordering | |
| P/N | F200 |
Peak UVA intensity measured at specified working distance with lamp at operating temperature. Actual intensity may vary with lamp age, ambient temperature, and working distance. Always wear UV-rated eye protection during operation.