Back to F-Series™ F200 — Technical Datasheet

F200 — Compact UV Arc Flood Curing Lamp

Incure F200 steps up from the F100 with 56% more intensity — 350 mW/cm² vs 225 mW/cm² — in the same 11 lb, 8″×6″ bench-mount housing. The 600W arc lamp cuts cure cycles where the F100's 400W falls short, without adding programming complexity. When the F200P's LCD timer is more than the process needs, the F200 delivers the same 350 mW/cm² with a simple rocker switch, an elapsed hour meter, and nothing to program.

56% More Intensity Than the F100 in the Same Housing

Same 8″×6″ curing area and 11 lb bench-mount form factor as the F100. The F200's 600W metal halide lamp produces 350 mW/cm² UVA at 2.0″ — against the F100's 225 mW/cm² from its 400W lamp. When cure time is the bottleneck and the F100's output is the constraint, the F200 is the direct step-up: same footprint, no new training, proportionally shorter cycles.

Shortens Cure Cycles Without Programming Overhead

Where the F200P's programmable timer and LCD keypad are more than a process requires, the F200 delivers the same 350 mW/cm² intensity with a rocker switch and an elapsed hour meter. Operators start and stop manually; the elapsed hour meter tracks lamp usage for scheduled maintenance. Compatible with the Incure B500 UV cure chamber for enclosed batch curing.

350 mW/cm² Across the Full 8″×6″ Area

600W metal halide arc lamp, UVA/UVB/visible to 420 nm. 175 mW/cm² at 3.0″. Forced-air cooling, auto-ranging 100–120/200–240 VAC. ~2,000-hour lamp life. 11 lb, 11″×10″×9″. UV Protective Goggles Included.

Incure F200 compact UV arc flood curing lamp with rocker switch and elapsed hour meter
Specifications
ModelF200
System TypeCompact UV Flood Curing System
Lamp Type600W Metal Halide Arc Lamp
Spectral OutputUVA (315–400 nm), UVB (280–315 nm), Visible to 420 nm
Curing Area8″ × 6″
Output Intensity
UVA Peak Intensity @ 2.0″350 mW/cm²
UVA Peak Intensity @ 3.0″175 mW/cm²
Power & Electrical
Input Voltage100–120 / 200–240 VAC ±10%, auto-ranging
Input Frequency50 / 60 Hz
Physical
Weight11 lb
Dimensions11″ × 10″ × 9″
ControlRocker Switch; Elapsed Hour Meter
CoolingForced Air
Lamp Life~2,000 hours
Chamber CompatibilityCompatible With Incure B500 UV Cure Chamber
Safety EquipmentUV Protective Goggles Included
Ordering
P/NF200

Peak UVA intensity measured at specified working distance with lamp at operating temperature. Actual intensity may vary with lamp age, ambient temperature, and working distance. Always wear UV-rated eye protection during operation.