C141C — UV LED Curing Chamber, 11.8″ × 11.8″ × 11.8″ Interior
Incure C141C is the general-purpose batch curing chamber in the C-Series™ — the mid-range cubic enclosure for assemblies, multi-component loads, and production batches where the compact C131C's 7.1-inch cube is too small and the C191C's large-format space is more than the process requires. Unlike the C131C, the C141C includes an adjustable shelf that sets the lamp-to-part curing distance across the full 11.8-inch internal height, adapting the chamber to the specific LED lamp and part geometry without hardware changes.
Adjustable Shelf — Set the Curing Distance the C131C Cannot
The C131C has a fixed chamber height with no shelf — the lamp-to-part distance is determined by the 7.1-inch internal space and cannot be adjusted. The C141C's adjustable shelf positions the part at any height within the 11.8-inch internal space, letting the engineer optimize the curing distance for the specific LED array and adhesive without changing the chamber or lamp. For processes that require a defined irradiance value at the part surface — not just the lamp's rated output — this adjustability is what makes process documentation possible.
Cures Multiple Components Per Cycle — No Limit to One Part at a Time
The 11.8″ × 11.8″ internal floor area accommodates multiple components, tray fixtures, or a single larger assembly in a single cure cycle — eliminating the one-part-at-a-time constraint of the C131C's 7.1-inch cube. For batch testing, production qualification runs, and low-to-medium volume assembly processes where throughput matters, the C141C increases cycle productivity without changing the lamp, the adhesive, or the cure parameters.
11.8″ × 11.8″ × 11.8″ Internal Space — Full L11-to-L44 Compatibility in a 14.2″ External Cube
Internal curing dimensions: 11.8″ × 11.8″ × 11.8″ (300 mm × 300 mm × 300 mm); external: 14.2″ × 14.2″ × 14.2″ (361 mm × 361 mm × 361 mm). Compatible with L11, L22, L33, and L44 UV LED flood lamps. Adjustable shelf; drawer-activated UV shut-off; foot-switch / PLC / RS-232 control interface; forced-air cooling with louvers. No integrated temperature sensor.
| Dimensions | |
| Model | C141C |
| Internal Curing Space | 11.8″ × 11.8″ × 11.8″ (300 mm × 300 mm × 300 mm) |
| External Dimensions | 14.2″ × 14.2″ × 14.2″ (361 mm × 361 mm × 361 mm) |
| Compatible Equipment | |
| Compatible UV LED Flood Lamps | L11 / L22 / L33 / L44 |
| Lamp Mounting | Tool-Free, Top-Mounted |
| Safety & Control | |
| Door Safety Interlock | Drawer-Activated UV Shut-Off |
| Shelf | Adjustable Shelf / Curing Distance |
| Control Interface | Foot-Switch / PLC / RS-232 |
| Housing | |
| Cooling | Forced-Air With Louvers |
| Chamber Temperature Sensor | Not Included |
| Ordering | |
| P/N | C141C |
The C141C is compatible with L11, L22, L33, and L44 UV LED flood lamps only. For flat substrates requiring horizontal drawer loading, specify the C131D (11.8″ × 11.8″ × 3.1″ drawer). For single-component or R&D samples where bench footprint must be minimized, specify the C131C (7.1″ × 7.1″ × 7.1″). For L88, L1010, L1212, or L1414 lamps — which exceed the L44's 4-inch × 4-inch footprint — specify the C191C (19.7″ × 19.7″ × 13.8″ internal).