L9000-LG Long Guide — 118 mm UV Lightguide
Incure L9000-LG Long Guide addresses the application the Short Guide cannot reach — automated production fixtures where the bond face is recessed deep inside the fixture envelope and the controller must sit outside it. At 118 mm, the Long Guide places the cure point 79% further from the controller body than the Short Guide. The controller mounts on the fixture frame or gantry; the guide tip enters the fixture and reaches the adhesive. Delivers the same 7,500 mW/cm² output at 9 mm and the same wavelength options as the Short Guide and Cool Guide when paired with the L9000™ controller — only the reach changes.
Reaches Cure Points the Short Guide Cannot Access
At 118 mm total length, the Long Guide enters fixture cavities, recessed board mounting positions, and multi-stage assembly frames where 66 mm of guide length runs out before the tip reaches the bond face. The extended fibre optic maintains full UV transmission across the additional length — there is no intensity penalty for the longer reach beyond what focal point physics dictates at any given tip-to-surface distance.
Keeps the Controller Outside the Fixture Envelope
In automated line fixtures, the controller body cannot enter the work envelope — robotic arms, conveyor tooling, and clamping mechanisms occupy the space around the assembly. The Long Guide's 118 mm length provides enough clearance to mount the controller on the fixture frame while the guide tip is positioned at the cure point inside the fixture. This is the configuration that enables full automation integration: controller on the frame, tip on the part, RS-232 trigger from the line controller.
7,500 mW/cm² at 9 mm Through 118 mm of Fibre Optic
Same peak irradiance as the Short Guide and Cool Guide at every measured focal point distance. At 9 mm: 7,500 mW/cm². At 17 mm: 2,300 mW/cm². At 25 mm: 450 mW/cm². Spot diameters 3–12 mm (6 options). Wavelength factory-configured at order (365 / 375 / 385 / 395 / 405 nm); intensity 10–100% adjustable via the L9000™ controller. Up to 4 Long Guides run simultaneously from one L9000™ controller — cure four deep-reach positions in one trigger cycle.
| Lightguide Specifications | |
| Model | L9000-LG |
| Guide Type | Long Guide — Extended Straight Cylindrical Fibre Optic |
| Total Guide Length | 118 mm |
| Spot Diameter Options | 3 mm / 4 mm / 6 mm / 8 mm / 10 mm / 12 mm (6 options) |
| Cable Lengths Available | 2,000 mm · 3,000 mm · 5,000 mm |
| LED Life (Controller) | 15,000 hours |
| UV Output & Configuration (365 nm, 100% Intensity) | |
| LED Wavelength Options | 365 nm / 375 nm / 385 nm / 395 nm / 405 nm (factory-configured at order) |
| Intensity Range | 10–100%, adjustable via the L9000™ controller |
| Irradiance at 9 mm Focal Point | 7,500 mW/cm² |
| Irradiance at 10 mm Focal Point | 5,000 mW/cm² |
| Irradiance at 17 mm Focal Point | 2,300 mW/cm² |
| Irradiance at 20 mm Focal Point | 1,200 mW/cm² |
| Irradiance at 25 mm Focal Point | 450 mW/cm² |
| Irradiance at 30 mm Focal Point | 223 mW/cm² |
| Ordering | |
| P/N Format | L9000-LG-[Wavelength]-[Guides]G-[Length] |
| Wavelength Code | 365 / 375 / 385 / 395 / 405 |
| Guides Code | 1G / 2G / 3G / 4G |
| Length Code (mm) | 2000 / 3000 / 5000 |
| Example P/N | L9000-LG-365-1G-2000 |
Irradiance values measured at 100% output intensity, 365 nm configuration, tip-to-surface focal point distances as indicated. The Long Guide maintains equivalent irradiance vs the Short Guide at all measured focal distances — extended fibre optic length introduces no additional intensity reduction beyond normal propagation losses. Spot diameter is determined by the lightguide tip selection at order. Controller LED life rated at 15,000 operating hours; no recalibration required.