S20™ 2-Pole — Dual-Point UV Arc Spot Curing Lamp
Incure S20-2P splits the S20™'s output equally across two lightguide tips, curing two bond points simultaneously in a single trigger cycle. Powered by a 200W mercury arc lamp with broad-spectrum 300–550 nm output and a programmable 1–99 second timer, the S20-2P doubles throughput on symmetrical assemblies and dual-joint bonding fixtures without additional controllers or equipment. Available with Ø3 mm lightguide tips in standard lengths from 0.75 m to 2 m.
Two Bond Points — One Trigger Cycle
Two lightguide tips fire simultaneously from a single trigger, curing two bond points in the same exposure time as one — cutting cycle time in half on dual-joint fixtures compared to sequential single-point curing.
No Second Controller Required
One lamp, one controller, two outputs. Eliminates the capital cost of a second spot curing system and simplifies fixture wiring, cabinet layout, and process control programming.
Equal UV Split to Both Tips
Matched irradiance at both lightguide outputs ensures a consistent UV dose at every cure point — no variation between left and right joints, no fixture-to-fixture cure inconsistency. Safety goggles included.
| Specifications | ||
| Model | S20-2P | |
| 100–120 VAC | 200–240 VAC | |
| AC Input Voltage | 100–120VAC ±10% | 200–240VAC ±10% |
| AC Input Current | 4.7 Amperes | 2.5 Amperes |
| Source Input Frequency | 47 Hz to 63 Hz | |
| Lamp Power Regulation | ±1.0% | |
| Fan / Auxiliary Voltage | 24V @ 0.5A | |
| Lamp Type | 200 Watt Mercury Arc | |
| Burning Position | Horizontal | |
| Radiation Flux | 300–550 nm | |
| Warm-up Time | 1 to 2 minutes | |
| Cooling Time Before Restart | 2 to 5 minutes typical | |
| Output Intensity (Typical) | >21 W/cm² UVA (at source) | |
| Output Intensity Range | 25–100% adjustable | |
| Timer Range | 1–99 seconds (programmable) | |
| Lamp Life | >2,000 hours typical | |
| Operating Temperature | +10°C to +40°C / +50°F to +104°F | |
| Relative Humidity | 30–75% operating, 10–100% storage | |
| Cooling | Dual DC Fans, Filtered | |
| Over-temp Shutdown | 65°C (internal) | |
| Lightguide Configuration — S20-2P | ||
| Lightguide Poles | Dual-Pole (2 Outputs) | |
| Lightguide Type | UV Liquid Lightguide | |
| Tip Diameters Available | Ø3 mm | |
| Lightguide Lengths | 0.75 m, 1 m, 1.5 m, 2 m (custom available) | |
| Physical | ||
| L × W × H (Controller) | 10.6" × 8.7" × 4.1" | |
| Weight | 6.0 lbs (2.7 kg) | |
| Safety Equipment | UV Protective Goggles Included | |
| Ordering | ||
| P/N Format | S20-2P-[Length] | |
| Length Code (mm) | 750 / 1000 / 1500 / 2000 | |
| Example P/N | S20-2P-750 | |
Output intensity is measured at the lightguide tip with the system operating at 100% power. Actual irradiance may vary depending on lightguide length, tip diameter, and the condition of the lightguide and optical components.